Technical Calculation Centre
Professional tools for sizing spray nozzles, pumps, pipework, flow rate, coverage, droplet size and compressed-air consumption.Size a Complete Spray System
Provides an initial estimate of total flow rate, required pump pressure, pressure losses, pipe velocity and internal pipe diameter.
This new calculator currently opens in Spanish. Size the systemSpray Angle and Coverage
Calculates theoretical spray width from the nozzle angle and working distance, helping define nozzle spacing and overlap.
Calculate coverageFlow Rate at a Different Pressure
Estimates nozzle flow when the actual working pressure differs from the reference pressure stated in the technical data.
Calculate flow rateCalculate the K Factor
Determines a nozzle’s discharge coefficient and makes it easier to convert between pressure and flow rate.
Calculate K FactorDroplet Size Dv0.5
Estimates the volume median diameter in microns according to nozzle type, flow rate, pressure and spray angle.
This new calculator currently opens in Spanish. Calculate droplet sizeInteractive Spray Simulator
Illustrates how pressure, viscosity, wind and spray angle can affect the spray pattern and atomisation behaviour.
Open simulatorSelect a Nozzle Material
Compares materials according to chemical resistance, temperature, corrosion, wear and operating conditions.
Select materialSeries W Air Consumption
Estimates blow-nozzle consumption in NL/min, Nm³/h and SCFM, together with an indicative energy cost.
Calculate air consumptionNozzles on a Spray Bar
Calculates nozzle quantity, spacing, overlap and total flow rate for an industrial flat-fan spray bar.
Size the spray barCalculate first and select with greater confidence. Compare the results with the product data for flow rate, pressure, spray pattern, connection, material and droplet size.
View available spray nozzlesCalculators for selecting and sizing spray nozzles more accurately
This calculation centre brings together tools for system flow rate, pump pressure, pipework, spray coverage, pressure correction, K Factor, Dv0.5 droplet size, material selection, spray simulation, compressed-air consumption and spray-bar sizing. The results provide an initial technical reference and make it easier to compare the available nozzle models.
Why calculate before selecting a spray nozzle?
A spray nozzle determines the spray pattern, coverage, liquid or air consumption, required operating pressure, droplet size, impact and resistance to temperature, chemicals, abrasion and corrosion.
Selecting a nozzle only by its thread size can lead to uneven coverage, excessive consumption, insufficient pressure, poor cleaning, inadequate drying, spray drift or premature wear.
Recommended order for sizing a spray system
This workflow takes you from the application —washing, cooling, humidifying, atomising, drying or blowing— to a more reliable preliminary selection.
Estimate the complete system first
The spray-system sizing calculator combines nozzle quantity, individual flow rate, required nozzle pressure, pipe data, pressure losses and pump allowance. Its interface is currently in Spanish.
Determine spray width and overlap
Use the spray-angle and coverage calculator to estimate theoretical spray width from the angle and working distance.
Correct flow rate for the real pressure
The flow-rate calculator shows how consumption changes when the actual pressure differs from the reference pressure used to specify the nozzle.
Check the K Factor
The K Factor tool describes the hydraulic relationship between pressure and flow rate and makes it easier to compare different nozzle references.
Estimate droplet size
The Dv0.5 calculator estimates the volume median diameter according to nozzle type, flow rate, pressure and angle. Its interface is currently in Spanish.
Size the spray bar
The spray-bar calculator helps determine nozzle quantity, spacing, overlap and total flow rate.
Select a suitable material
The material guide and selector supports comparison of PVDF, stainless steel, brass, POM/Delrin and polypropylene.
Calculate compressed-air consumption
For drying, cooling and blow-off, the Series W consumption calculator estimates the required air flow and indicative operating cost.
Review spray behaviour visually
The interactive spray simulator illustrates the influence of pressure, viscosity, wind and angle.
All tools and when to use them
Combines total flow rate, required pressure, pipe velocity and pressure losses.
Size the systemCalculates theoretical coverage from nozzle angle and distance to the target surface.
Calculate coverageConverts a known nozzle flow rate to another operating pressure.
Calculate flow rateDetermines the discharge coefficient used to describe and compare nozzles.
Calculate K FactorEstimates droplet size in microns from spray pattern, flow rate, pressure and angle.
Calculate droplet sizeProvides a visual reference for the effects of pressure, viscosity, wind and angle.
Open simulatorSupports preliminary selection by fluid, temperature, corrosion and mechanical demand.
Select materialEstimates air demand and cost for blowing, drying, cleaning and cooling.
Calculate consumptionCalculates nozzle quantity, spacing, overlap and total liquid demand.
Size the spray barNote: the two newest calculators for complete system sizing and droplet size are fully functional, but their interfaces currently open in Spanish.
Key variables to review before selecting a spray nozzle
| Variable | Technical importance | Recommended tool |
|---|---|---|
| Nozzle quantity and total flow rate | The pump and pipework must supply every nozzle operating at the same time. | System sizing |
| Spray angle | Together with distance, it defines theoretical width and required overlap. | Angle and coverage |
| Working distance | Changes coverage, impact and the practical distribution of the spray. | Coverage calculator |
| Operating pressure | Affects flow rate, outlet velocity, spray pattern and atomisation. | Flow rate by pressure |
| Pump pressure and pressure losses | The pump must cover nozzle pressure, elevation, line losses and an appropriate allowance. | Pump and pipework |
| Droplet size Dv0.5 | Influences evaporation, drift, wetting, impact and heat transfer. | Droplet size |
| Nozzle material | Chemical compatibility, temperature and abrasion affect service life. | Material selection |
| Compressed-air consumption | In blowing and drying processes, the compressor is often the main operating-cost factor. | Series W calculator |
Typical industrial applications
Coverage, overlap, flow rate and operating pressure support the design of more uniform washing lines.
View flat-fan nozzlesSpray pattern, droplet size and flow rate must match the required heat-transfer process.
View full-cone nozzlesPressure, droplet size, consumption and material are critical for mist and air-water applications.
View hydropneumatic nozzlesThe air-consumption calculator supports compressor sizing and energy assessment.
View Series W blow nozzlesCoverage, pressure and droplet size should be considered together to limit drift and over-wetting.
View hollow-cone nozzlesThe tools help identify restrictions involving pressure, pipework, consumption, coverage or material.
Compare available referencesCommon sizing mistakes
- Selecting only by thread size: identical connections do not mean identical flow rate, angle, spray pattern or material.
- Underestimating total flow rate: individual nozzle consumption must be multiplied by the number of simultaneously active nozzles.
- Ignoring pressure losses: long pipe runs, small diameters, elevation changes and fittings reduce the pressure available at the nozzle.
- Not correcting flow for actual pressure: a change in pressure changes real consumption.
- Allowing insufficient overlap: this can create dry bands or uneven treatment.
- Treating Dv0.5 as one uniform droplet size: the value represents a distribution, not every individual droplet.
- Using an unsuitable material: fluid, temperature and abrasion can greatly reduce service life.
- Ignoring compressed-air cost: compressor energy consumption can exceed the nozzle purchase cost by a wide margin.
Frequently asked questions
Do the calculators replace the product technical data?
No. They support an initial estimate and scenario comparison. Results must be checked against the data and operating limits of the specific nozzle.
Which calculator should be used first?
For a new system, complete installation sizing is a useful starting point. Then review coverage, pressure correction, droplet size, spray-bar layout, material and, where relevant, compressed-air consumption.
How is total nozzle flow rate calculated?
Multiply the flow rate of one nozzle at the intended operating pressure by the number of nozzles running at the same time. Any additional allowance depends on the system.
What does Dv0.5 mean?
Dv0.5 is the volume median diameter. Approximately 50% of the sprayed liquid volume is contained in smaller droplets and 50% in larger droplets.
Are all droplets the same size as Dv0.5?
No. A nozzle generates a droplet-size distribution. Dv0.5 is a representative value within that distribution.
How does pressure affect droplet size?
Higher pressure often produces stronger atomisation and smaller average droplets. Actual behaviour still depends on nozzle design, flow rate and liquid properties.
How many nozzles does a spray bar require?
You need the total width, working distance, spray angle and desired overlap. The calculator estimates nozzle quantity, spacing and total flow rate.
Which nozzle material is best?
It depends on the fluid, temperature, pressure, abrasion and environment. No single material is optimal for every application.
Compare the results with the available spray nozzles
Once total flow rate, operating pressure, coverage, droplet size, material and consumption have been narrowed down, the product technical data can be compared more efficiently.