Fast shipping
Products available from stock
Automatic quantity discounts
No minimum order
UK: Free DAP Shipping over €400

CA06 – WATER CURTAIN – METRIC 10 (M-10) – 70º – 4,5 LIT/MIN @3BAR (Brass)

6,95€

(Less quantity discount applied in cart)

  • 5+ pcs −3%
  • 10+ −5%
  • 20+ −7%
  • 50+ −10%
  • 100+ −12%

The flat spray nozzle CA-06 has the same technical specifications as the reference CA-14 but thread metric 10.

AC-SERIES <encoded_tag_closed /> Flat Sprinkler (Water Consumption and Effects)
Sheet

🔥Only 99 units left. ⏳Order now before they sell out!⏳

🔥 Volume discount
TitleRangeDiscount
No. of nozzles / Discount5 - 9 3%
No. of nozzles / Discount10 - 19 5%
No. of nozzles / Discount20 - 49 7%
No. of nozzles / Discount50 - 99 10%
No. of nozzles / Discount100 - 200 12%

Description

CA06 M10 nozzle for 70° water curtain

The CA06 is a hydraulic nozzle designed to produce a water curtain or flat jet with a nominal angle of 70°. Its outlet geometry turns the flow into a fan-shaped sheet to distribute water across a surface.

This version is made of 303 stainless steel and uses an M10 metric threaded connection. It delivers a nominal flow rate of 4.5 litres per minute at 3 bar, equivalent to approximately 270 litres per hour under those conditions.

The nozzle is supplied with an O-ring located between the body and the threaded connection. This O-ring helps seal the nozzle in a compatible housing and reduces the risk of leaks at the mounting point.

The hexagonal body makes it easier to fit with a suitable tool. The front slot shows the direction of the fan and lets you orient the water curtain. The DA and CA-06 markings let you recognise the reference at a glance.

The CA06 belongs to the CA family of water curtains and sheets. You can also browse the full catalogue of flat spray nozzles and water curtains.


Main features

  • Output pattern: water curtain or flat fan.
  • Nominal angle: 70°.
  • Nominal flow rate: 4.5 L/min at 3 bar.
  • Hourly consumption: 270 L/h at 3 bar.
  • Connection: M10 metric thread.
  • Material: 303 stainless steel.
  • Sealing: O-ring included.
  • Body: hexagonal for easier fitting.
  • Orientation: front slot showing the fan direction.
  • Identification: DA and CA-06 markings.
  • Sales unit: 1 nozzle with O-ring.

To compare stainless steel with PVDF, brass, polypropylene or Delrin, use the nozzle materials guide and selector.


Technical specifications

ReferenceCA06
Product typeFlat spray hydraulic nozzle
Output patternWater curtain / flat fan
Reference fluidWater
Nominal angle70°
Nominal flow rate4.5 L/min at 3 bar
Nominal hourly flow rate270 L/h at 3 bar
Theoretical K factor2.598 L/min/√bar
ConnectionM10 metric thread
Body material303 stainless steel
Sealing systemO-ring included
FinishNatural machined stainless steel
Body shapeHexagonal
IdentificationDA / CA-06 marking
Contents1 CA06 nozzle and 1 O-ring

See other products classified as components made of 303 stainless steel.


CA06 flow rate by pressure

The nominal figure for the CA06 is 4.5 L/min at 3 bar. In a fixed-geometry hydraulic nozzle, flow varies approximately with the square root of pressure:

Q₂ = Q₁ × √(P₂ ÷ P₁)

From the nominal flow rate a theoretical K factor of 2.598 L/min/√bar is obtained.

PressureEstimated flow rateHourly consumption
1 bar2.60 L/min156 L/h
2 bar3.67 L/min220 L/h
3 bar4.50 L/min270 L/h
4 bar5.20 L/min312 L/h
5 bar5.81 L/min349 L/h
6 bar6.36 L/min382 L/h
8 bar7.35 L/min441 L/h
10 bar8.22 L/min493 L/h

The values are theoretical estimates for water. The actual result may vary because of tolerances, pressure losses, temperature, viscosity, filtration, wear and installation conditions.

Calculate other operating points with the nozzle flow rate by pressure calculator.

You can also read the guide on the K factor of a nozzle and the technical article on pressure, flow rate and K factor.


70° angle and coverage width

The theoretical width of the curtain increases with the distance between the nozzle and the surface. For a nominal angle of 70°, the following values can be used as a reference:

DistanceTheoretical width
100 mm140 mm
200 mm280 mm
300 mm420 mm
500 mm700 mm

The actual useful coverage depends on pressure, the condition of the orifice, the fluid, the orientation, the distance and the effective definition of the fan edges.

Enter the angle and distance in the spray angle and coverage calculator.


Typical applications

  • Washing and rinsing parts.
  • Distributing water over surfaces.
  • Cleaning conveyor belts.
  • Wetting materials or processes.
  • Cooling surfaces.
  • Surface treatment and preparation.
  • Bars fitted with several flat spray nozzles.
  • Installations with an M10 metric connection.

Final suitability depends on pressure, required flow rate, temperature, distance, the liquid and the chemical compatibility of the installation.

If you are going to use several units, see the guide on how to size a nozzle installation: flow rate, pump, pressure and piping.


O-ring included

The CA06 includes a sealing O-ring fitted between the nozzle body and the connection area.

For the O-ring to work properly, the seating surface and the housing must be compatible with its shape and dimensions. Before fitting, check that the O-ring is clean, correctly positioned and free of cuts, deformation or damage.

The chemical and thermal compatibility of the O-ring will depend on its material. If the nozzle is going to work with chemicals, high temperatures or fluids other than water, the compatibility of the O-ring must be confirmed beforehand.


Installing the CA06 M10 nozzle

  1. Check that the housing is compatible with an M10 metric thread.
  2. Check the thread pitch and the available length.
  3. Clean the thread and the surface on which the O-ring will rest.
  4. Check that the O-ring is correctly seated and undamaged.
  5. Screw the nozzle in by hand at first to avoid damaging the thread.
  6. Do the final tightening on the hexagonal body.
  7. Do not use the front slot as a tightening point.
  8. Do not overtighten or compress the O-ring more than necessary.
  9. Orient the slot to aim the water curtain correctly.
  10. Pressurise gradually and check that there are no leaks.

The sealing system must be validated in the real installation. The O-ring supplied does not replace checking the compatibility of the housing, pressure, temperature and fluid.


Cleaning and maintenance

  • Fully depressurise the system before removing the nozzle.
  • Use sufficiently clean water and suitable filtration.
  • Inspect the slot and the internal passage periodically.
  • Do not insert wires or tools that alter the geometry.
  • Check the flow rate if the shape of the fan changes.
  • Check the O-ring whenever the nozzle is removed.
  • Replace the O-ring if it shows cuts, hardening or deformation.
  • Clean the seating surface before refitting.

A higher-than-expected flow rate may indicate wear. A lower flow rate or an irregular fan may indicate blockage, dirt or insufficient pressure.


What is supplied

  • 1 CA06 water curtain nozzle.
  • 1 sealing O-ring.
  • Machined 303 stainless steel body.
  • Integrated M10 metric threaded connection.

Pipes, manifolds, filters, fittings and tools are not included unless expressly stated.


Related alternatives


Frequently asked questions about the CA06

What type of output does it produce?

It produces a water curtain or flat jet with a nominal angle of 70°.

What is its flow rate?

The nominal flow rate is 4.5 L/min at 3 bar, equivalent to 270 L/h.

What connection does it use?

It uses an M10 metric threaded connection. The pitch, the usable length and the O-ring housing must be checked before fitting.

Does it include an O-ring?

Yes. The CA06 nozzle is supplied with an O-ring to help seal it in a compatible housing.

What material is the O-ring made of?

The O-ring material is not specified in this data sheet. If it is going to be used with chemicals, high temperatures or fluids other than water, its compatibility must be confirmed beforehand.

What is the nozzle made of?

The body of this version is machined from 303 stainless steel.

What K factor does it have?

Its theoretical K factor, calculated from 4.5 L/min at 3 bar, is approximately 2.598 L/min/√bar.

Does the flow rate change when the pressure changes?

Yes. In a fixed-geometry hydraulic nozzle, flow varies approximately with the square root of pressure.

Can the curtain be oriented?

Yes. The mounting position lets you orient the fan. The front slot helps identify the direction of the flat jet.

Can it be used with other liquids?

The hydraulic data are given for water. For other liquids, the compatibility of 303 stainless steel, the O-ring and the rest of the installation must be checked.

How can I confirm that it is suitable for my installation?

You need to know the actual pressure, the flow rate, the required width, the distance, the fluid, the temperature and the connection. If you need help, you can contact Boquillas de Aspersión.


Calculators and technical resources


Technical summary

The CA06 is a hydraulic 70° flat spray nozzle made of 303 stainless steel, with an M10 metric connection and an O-ring included. It delivers a nominal flow rate of 4.5 L/min at 3 bar, equivalent to 270 L/h.

See all water curtains and flat spray nozzles or ask for technical advice.

Additional information

Weight0,011 kg
Dimensions1,8 × 1,8 × 1,2 cm
Material

Thread