FC-02 – 80° flat fan nozzle – 2.3 mm slot – 12.5 L/min at 3 bar – AISI 303

8,45€

(Less quantity discount applied in cart)

  • 5+ pcs −3%
  • 10+ −5%
  • 20+ −7%
  • 50+ −10%
  • 100+ −12%

The FC-02 is an 80° flat fan nozzle in AISI 303 stainless steel, with an outlet slot 2.3 mm wide and a nominal flow rate of 12.5 L/min at 3 bar. It can be assessed for washing, rinsing and wetting industrial surfaces.

  • Nominal consumption: 750 L/h per nozzle.
  • Hexagonal body and male threaded connection.
  • Thread size and standard to be confirmed.

🔥Only 50 units left. ⏳Order now before they sell out!⏳

🔥 Volume discount
TitleRangeDiscount
No. of nozzles / Discount5 - 9 3%
No. of nozzles / Discount10 - 19 5%
No. of nozzles / Discount20 - 49 7%
No. of nozzles / Discount50 - 99 10%
No. of nozzles / Discount100 - 200 12%
SKU: FC-02 Category: Tag: Brand:

Description

FC-02: 80° flat fan nozzle in AISI 303 stainless steel

The FC-02 flat fan nozzle has an outlet slot 2.3 mm wide, a nominal spray angle of 80° and a declared flow rate of 12.5 L/min at 3 bar. Its slotted geometry corresponds to a flat fan nozzle designed to apply liquid to a strip of surface.

The photographs show the rounded head, slotted outlet, hexagonal body and male threaded connection. The actual liquid distribution and exact spray direction must be checked with a spray test.

FC-02 technical specifications

Reference and SKUFC-02
TypeHydraulic flat fan nozzle
Declared materialAISI 303 stainless steel
Nominal spray angle80°
Outlet slot width2.3 mm
Declared nominal flow rate12.5 L/min at 3 bar
Nominal hourly consumption750 L/h at 3 bar
ConnectionMale thread; size and standard to be confirmed
InstallationHexagonal body for wrench engagement

The 2.3 mm dimension is the slot width: it is neither the thread size, the diameter of a circular orifice nor the internal free passage. The material, angle, slot width and nominal operating point come from the data supplied for this reference.

Flow rate versus pressure

For water and a hydraulic nozzle with fixed geometry, the flow rate can be estimated using Q₂ = 12.5 × √(P₂/3), with Q in L/min and P in bar. The calculated coefficient is K ≈ 7.22 L/min/√bar.

Differential pressureEstimated flow rate
1 bar7.2 L/min
2 bar10.2 L/min
3 bar12.5 L/min — declared nominal operating point
4 bar14.4 L/min
5 bar16.1 L/min
6 bar17.7 L/min

Theoretical table for water or a liquid with similar behaviour, calculated from the nominal operating point. It is not a tested curve and does not establish the permissible pressure range. When discharging to the atmosphere, differential pressure approximately equals the gauge supply pressure at the nozzle. Viscosity, wear and actual operating conditions can change the flow rate.

80° spray angle and fan width

The theoretical geometric width is calculated using W = 2 × H × tan(40°), with W and H expressed in the same units. H is the distance to a surface perpendicular to the fan axis.

Distance to surfaceTheoretical geometric width
10 cm16.8 cm
20 cm33.6 cm
30 cm50.3 cm
50 cm83.9 cm

The calculation assumes that the 80° angle is maintained. It does not guarantee uniform coverage or directly determine nozzle spacing. On spray bars, adjust height, orientation and overlap by checking the actual spray pattern.

Applications to assess

  • Washing and rinsing industrial parts and surfaces.
  • Wetting belts and surfaces by applying liquid in a strip.
  • Installation on spray bars and manifolds, after checking the connection, simultaneous flow demand and coverage.

Selection depends on the required result, contamination, liquid, pressure and distance. Cleaning effectiveness must be validated under the process conditions.

Total consumption and pump selection

At 3 bar, four FC-02 nozzles consume 50 L/min and ten FC-02 nozzles consume 125 L/min, equivalent to 7,500 L/h for ten units. Total consumption is calculated by multiplying the flow rate per nozzle by the number operating simultaneously.

The pump must deliver that flow while maintaining the required pressure at the nozzles and compensating for losses in pipes, filters and valves, as well as elevation differences. Check pressure while all outlets are operating.

Material and liquid compatibility

The declared material for the FC-02 is AISI 303 stainless steel. Before using detergents or other liquids, check compatibility considering composition, concentration, temperature and exposure time. The product pressure and temperature limits must be confirmed before finalising the selection.

Installation and maintenance

  1. Identify the thread size, pitch and standard of the nozzle and its mounting port.
  2. Install with a wrench on the hexagon, avoiding force on the head.
  3. Align the fan and test the spray with the actual liquid, pressure and distance.
  4. Select filtration according to the internal free passage and the particles in the circuit.
  5. Check flow rate and spray pattern regularly to detect blockage or wear.

Depressurise before removal. Use a cleaning method compatible with the material and avoid tools that could enlarge or deform the slot.

Frequently asked questions about the FC-02

How much liquid does the FC-02 consume at 3 bar?

The declared nominal flow rate is 12.5 L/min, equivalent to 750 L/h per nozzle.

What does 2.3 mm refer to?

The width of the outlet slot. This dimension does not identify the thread or determine the internal free passage.

What width does it provide at 20 cm?

For an 80° angle, the theoretical geometric width is 33.6 cm. The usable area and uniformity must be checked by testing.

How much do ten nozzles consume?

Ten FC-02 nozzles nominally consume 125 L/min at 3 bar, equivalent to 7,500 L/h.

Does it have a 1/4-inch thread?

The visible connection is male, but its size and standard have not yet been confirmed. They must be identified before purchasing a fitting or manifold.

Can it be used with chemicals?

The compatibility of AISI 303 must be checked with the specific chemical, concentration and temperature of the process.

Resources for selection and sizing

Additional information

Weight0,002 kg
Dimensions1,6 × 1,6 × 2,3 cm
Angle

80º

Flow rate

12.5 L/min @ 3 bar

K factor

7.22

You may also like…