Fast shipping
Products available from stock
Automatic quantity discounts
No minimum order
UK: Free DAP Shipping over €400

DA01 – ATOMISING NOZZLE FOR DIESEL BURNER – 60° – 1.89 LITRES/HOUR @10 BAR – 9/16-24 UNEF – BRASS

10,45€

(Less quantity discount applied in cart)

  • 5+ pcs −3%
  • 10+ −5%
  • 20+ −7%
  • 50+ −10%
  • 100+ −12%

DA-01 atomising nozzle for fuel burners, featuring a solid-cone spray pattern, a 60° spray angle and an approximate droplet size of 100 μm. Flow rate: 1.87 L/h at 10 bar.

  • 9/16-24 UNEF male thread
  • Brass body
  • 45 μm sintered copper filter
  • Net weight: 28 g

Product information and technical specifications updated in September 2026.

🔥Only 50 units left. ⏳Order now before they sell out!⏳

🔥 Volume discount
TitleRangeDiscount
No. of nozzles / Discount5 - 9 3%
No. of nozzles / Discount10 - 19 5%
No. of nozzles / Discount20 - 49 7%
No. of nozzles / Discount50 - 99 10%
No. of nozzles / Discount100 - 200 12%

Description

DA-01 atomising nozzle for oil burners

The DA-01 is a single-fluid nozzle designed to atomise heating oil and other compatible liquid fuels in high-pressure burners. It produces a solid-cone spray pattern, identified by the letter S, with a nominal spray angle of 60°. It may also be used for humidification, dust suppression and evaporative cooling applications.

Its nominal capacity is 0.50 US gal/h. Under the European reference conditions specified for this model, it delivers a flow rate of 1.89 L/h at 10 bar. The specified nominal droplet size is 100 μm.

Main features

  • Solid-cone spray pattern.
  • Nominal spray angle of 60°.
  • Nominal capacity of 0.50 US gal/h — 1.89 L/h at 10 bar.
  • Nominal droplet size of 100 μm.
  • Compact brass body.
  • 9/16-24 UNEF American male thread.
  • Integrated 45 μm sintered copper filter.
  • Net weight of 28 g.

Technical specifications

 

SpecificationValue
ModelDA-01
TypeAtomising nozzle for oil burners
Atomisation systemSingle-fluid pressure atomisation
Spray patternSolid cone
Nominal spray angle60°
Nominal capacity0.50 US gal/h — 1.89 L/h
Nominal droplet size100 μm
Body materialBrass
Connection9/16-24 UNEF male thread
Integrated filterSintered copper
Filtration rating45 μm
Net weight28 g
Dimensions3.1 cm high × 1.7 cm diameter

 

60° solid-cone spray pattern

The spray pattern distributes the fuel throughout the interior of the spray cone. The nominal 60° angle provides a spray geometry commonly used in burners with medium-width combustion chambers.

The capacity, spray angle and spray pattern must match the specifications provided by the burner manufacturer.

Droplet size

The nominal droplet size specified for this model is 100 μm. The actual droplet size may vary depending on atomisation pressure, fuel viscosity, density and temperature, as well as nozzle wear or contamination.

45 μm sintered copper filter

The nozzle incorporates a porous sintered copper filter with a filtration rating of 45 μm. Its purpose is to retain particles before they reach the internal metering passages and outlet orifice.

This filter provides final-stage protection for the nozzle but does not replace the installation’s main fuel filter.

9/16-24 UNEF thread

The connection uses an American 9/16-24 UNEF male thread:

  • Nominal diameter: 9/16 inch, approximately 14.29 mm.
  • Thread count: 24 threads per inch.
  • Approximate pitch: 1.058 mm.
  • Type: Unified National Extra Fine thread.

This thread is not equivalent to a BSP, BSPT, GAS or metric connection. The nozzle must only be installed in a compatible 9/16-24 UNEF female nozzle holder.

Applications

  • High-pressure oil burners.
  • Compatible boilers and heat generators.
  • Furnaces equipped with liquid-fuel atomisation systems.
  • Industrial burners.
  • Maintenance and preventive replacement of fuel nozzles.

How to check compatibility

Before ordering, check the removed nozzle and the burner documentation for the following:

  1. Nominal capacity of 0.50 US gal/h — 1.89 L/h.
  2. Spray angle of 60°.
  3. Solid-cone spray pattern.
  4. 9/16-24 UNEF thread.
  5. Pump pressure setting; the nozzle requires a minimum operating pressure of 10 bar.
  6. Type of fuel approved for use with the equipment.

Matching the flow rate or external appearance alone does not guarantee that two nozzles are interchangeable.

Installation

  1. Disconnect the burner from the electrical supply and depressurise the fuel line.
  2. Clean the nozzle holder, taking care to prevent debris from entering the fuel passage.
  3. Do not touch the outlet orifice or internal components.
  4. Screw in the nozzle while holding it by the hexagonal flats.
  5. Do not force the thread or apply a tightening torque that has not been approved by the equipment manufacturer.
  6. Check the pump pressure and adjust the combustion settings after installation.

Installation and adjustment must be carried out by qualified personnel using suitable combustion-analysis equipment.

Maintenance

  • Do not insert needles, wires or tools into the outlet orifice.
  • Do not use abrasive materials to clean the calibrated components.
  • Check the main fuel filter regularly.
  • Replace the nozzle if it becomes blocked, worn or produces a distorted spray pattern.
  • Check the flame quality and combustion parameters after every maintenance procedure.

Package contents

  • 1 DA-01 atomising nozzle.
  • Integrated 45 μm sintered copper filter.

The nozzle holder, pump, pipework, electrodes, main filter and installation tools are not included.

Frequently asked questions

Does the 0.50 rating refer to litres per minute?

No. It refers to a nominal capacity of 0.50 US gallons per hour.

What spray pattern does this nozzle produce?

It produces a solid-cone spray pattern with a nominal angle of 60°.

What is the flow rate under the European reference conditions?

The technical data specifies a flow rate of 1.89 L/h at a pressure of 10 bar.

Will the droplet size always be 100 μm?

This is the specified nominal value. The actual result may vary depending on pressure, viscosity, temperature and the condition of the nozzle.

Does the integrated filter replace the installation’s fuel filter?

No. The 45 μm sintered filter protects the nozzle but does not replace the main fuel-filtration system.

Is it compatible with a 1/4-inch GAS thread?

No. The DA-01 uses an American 9/16-24 UNEF thread and requires a compatible nozzle holder.


Compatibility with Danfoss® nozzle holders

The DA-01 nozzle may be used as an alternative in certain nozzle holders and burners designed for standard-format 9/16-24 UNEF nozzles with a specification of 0.50 GPH, 60° and an S solid-cone spray pattern.

Before replacing the original nozzle, check the thread, dimensions, flow rate, spray angle, spray pattern and operating conditions of the burner.

Danfoss® is a registered trademark of its respective owner. It is used solely to indicate potential technical compatibility. The DA-01 is an independent product and is not manufactured, authorised, approved or sponsored by Danfoss. Compatibility must be verified for each individual installation.

Additional information

Weight0,028 kg
Dimensions1,7 × 1,7 × 3,1 cm
Material

Thread

Angle

60º

You may also like…