Identify your nozzle without a technical data sheet: model, BSPT thread, marking 6502/9515, flow rate and material. Find the replacement part and buy it from as little as 1 unit.

To identify an installed spray nozzle, check the spray pattern, thread, flow rate at a known pressure, spray angle, material and mounting configuration. The pattern and thread identify the likely nozzle family; flow rate, angle and material then help determine the correct replacement.

If you have a worn, clogged or damaged spray nozzle and do not know which replacement to order, this guide takes you through the identification process step by step. You do not necessarily need the original manufacturer’s catalogue: you need to observe the spray pattern and check the main measurable specifications. At the end, you can match these characteristics to the appropriate BOCASPER nozzle family and buy online with no minimum order quantity.

Summary in 6 steps
  1. Identify the spray pattern while the nozzle is operating or, where possible, from the outlet geometry.
  2. Measure the thread with a caliper and compare it with the BSPT dimensions.
  3. Read the nozzle marking and check whether it encodes spray angle and nominal capacity.
  4. Identify the material using appearance, weight and documentation where available.
  5. Decide whether the nozzle should be cleaned, the system corrected or the nozzle replaced.
  6. Select the replacement by spray family, connection, flow rate, angle and material.

1Identify the spray pattern

The spray pattern is one of the most important selection criteria and cannot be determined from the thread alone. If the system can be operated safely, observe the spray against a suitable background or target. If it cannot, the outlet geometry and internal design may provide useful clues, although the actual spray pattern should ultimately be confirmed from technical data or an operating test.

What you seeTypical outlet / design clueSpray patternTypical applicationBOCASPER family
Flat sheet with a linear impact patternElongated or shaped outlet, or deflector designFlat fan / water curtainLinear washing, rinsing, spray bars and surface coverageCA, CC, CW and CV Series
Filled circular spray patternRound outlet with an internal vane, insert or swirl geometry depending on the designFull coneCooling, wetting, washing and general circular coverageBA, BB, BC and BS Series
Ring-shaped spray with lower liquid density in the centreRound outlet with an internal or tangential swirl arrangementHollow coneCooling towers, humidification, gas treatment and dust controlAA, AB and AC Series
Fine mist or small dropletsSmall hydraulic passage, atomising geometry and sometimes an integrated filterFine spray / mistEvaporative cooling, humidification and low-consumption sprayingDB, DC and other fine-spray Series
Straight, concentrated jetRound outlet designed to minimise dispersionSolid stream / straight jetHigh-impact cleaning, localised cooling and long-reach applicationsSolid-stream Series
Separate air and liquid connectionsBody with two fluid connections or an air/liquid mixing arrangementTwin-fluid / hydropneumatic atomisationFine mist, dry fog, humidification and controlled atomisationG / GA Series

If your original nozzle uses a trade name from another manufacturer —such as VeeJet, FullJet, WhirlJet, SpiralJet or similar names— use the spray-pattern and industrial-application guide to identify the general type of nozzle first. Trade names can help identify a product category, but they do not establish equivalence, compatibility or interchangeability between specific references.

2Measure the thread before ordering

One of the most common mistakes is ordering a nozzle as “half-inch” after measuring its outside diameter with a tape measure. BSPT pipe threads use nominal inch sizes, so the stated thread size does not correspond directly to the outside diameter measured in millimetres.

Nominal BSPT threadApprox. male outside diameterThreads per inchTypical nozzle applications
1/8″9.7 mm28Misting, anti-drip systems and low-flow applications
1/4″13.2 mm19Common size for flat-fan, full-cone and fine-spray nozzles
3/8″16.7 mm19Medium-flow industrial applications
1/2″20.9 mm14Higher-flow spraying, washing and industrial systems
3/4″26.4 mm14Spiral nozzles, larger flow rates and wide coverage
1″33.2 mm11Large-flow nozzles, tank systems and pipe-cleaning applications

Measure the outside diameter of the male thread with a caliper, not the width across the flats of the hexagonal body. For a tapered thread, take the measurement around the middle of the threaded section. Also confirm whether the installation requires a male or female connection before ordering.

Complete BSPT thread guide →

Important: the same thread does not mean the same nozzle. Two nozzles with a 1/4″ BSPT connection may have completely different flow rates, spray angles, patterns, droplet sizes, materials and working-pressure ranges. The thread only confirms one part of the mechanical connection.
BSPT / GAS terminology: “GAS thread” is widely used commercially for BSP-type pipe threads, but the exact thread standard and whether it is tapered or parallel should always be confirmed from the product specification. Do not assume compatibility from the word “GAS” alone.

3Read the marking: it may reveal the spray angle and capacity

Many flat-fan spray-tip ranges use a four- or five-digit marking in which the first digits indicate the nominal spray angle and the remaining digits indicate a nominal flow-capacity code. A commonly used convention is illustrated below:

Example markingFirst digitsCapacity codeTypical interpretation in this coding convention
650265°0265° flat fan, nominal capacity 0.2 US gpm at 40 psi
951595°1595° flat fan, nominal capacity 1.5 US gpm at 40 psi
11004110°04110° flat fan, nominal capacity 0.4 US gpm at 40 psi
800380°0380° flat fan, nominal capacity 0.3 US gpm at 40 psi
Do not treat this marking system as universal. Coding conventions vary between manufacturers and nozzle ranges. Always confirm the exact reference against the current technical documentation whenever the manufacturer can be identified.

For metric conversion, 1 US gpm ≈ 3.785 L/min and 40 psi ≈ 2.76 bar. Under the coding convention above, a 9515 therefore corresponds to approximately 5.68 L/min at 40 psi. If the BOCASPER reference is specified at 3 bar, correct the flow for pressure before comparing the two values.

If there is no readable marking: measure the actual flow rate

Operate the nozzle at a known dynamic pressure, collect its discharge for a measured period and calculate the volume per minute. For water and other liquids with similar hydraulic behaviour, the flow of the same fixed hydraulic nozzle can be estimated at another pressure using:

Q₂ = Q₁ × √(P₂ / P₁)

Use the same pressure units for P₁ and P₂. The relationship is an approximation for the same nozzle and comparable fluid properties within the nozzle’s normal operating range. It should not be applied blindly to twin-fluid air/water nozzles, adjustable nozzles, eductors, rotary equipment or other devices whose performance depends on additional variables.

Doubling pressure does not double the flow rate. For a conventional fixed hydraulic nozzle, it increases theoretical flow by approximately √2 = 1.41 times.

Flow rate, pressure and K-factor guide → Spray angle and coverage calculator →

4Identify the nozzle material

Material affects chemical compatibility, temperature capability, corrosion resistance, wear and service life. Appearance, weight and magnetic response can provide useful clues, but they are not sufficient to identify an exact alloy or polymer grade. For critical applications, confirm the material from the product marking, technical documentation or supplier.

Typical cluePossible materialCommon strengthsImportant limitation
Low-density engineering plastic; often natural, white, black or colouredPolypropylene (PP)Good resistance to many aqueous chemicals, low weight and economical costTemperature, pressure, UV exposure and chemical limits depend on the specific PP grade
Hard, smooth, rigid engineering plastic; usually denser than PPDelrin / POM / acetalGood dimensional stability, stiffness and wear characteristicsChemical compatibility must be checked, particularly with strong acids and oxidising agents
Dense metal with yellow or gold appearanceBrassMachinability, clean-water applications, compressed air and economical industrial useCorrosion, dezincification and regulatory suitability depend on water chemistry and the exact alloy
Dense silver-grey metal; may be non-magnetic or weakly magnetic depending on grade and processingStainless steel, commonly AISI 303 / 304 / 316Mechanical strength, temperature capability and good corrosion resistanceMagnetism cannot reliably distinguish 303, 304 and 316; chloride resistance also varies by grade and conditions
White or cream engineering fluoropolymer, relatively dense for a plasticPVDFExcellent resistance to many aggressive chemicals and corrosive environmentsHigher cost; pressure and temperature limits must be checked for the exact component

Practical rule: if the nozzle being replaced has failed through corrosion, erosion or chemical attack, investigate the cause before installing the same material again. An eroded orifice may progressively increase flow and alter the spray distribution even when the nozzle still appears to operate.

Material selection and technical calculators →

5Clean, correct the system or replace the nozzle?

A poor spray pattern does not automatically mean that the nozzle is clogged, and a blockage does not automatically mean that the nozzle needs replacing. Diagnose the cause before changing components:

SymptomPossible causeRecommended first action
Deflected, streaked or asymmetrical sprayParticle, deposit, damaged orifice or incorrect orientationInspect and clean using a compatible method; replace the nozzle if the orifice is damaged
Weak or incomplete spray patternInsufficient dynamic pressure, restricted filter, valve or supply problemMeasure pressure close to the nozzle and inspect the supply system before replacing it
Ragged edges or progressive loss of spray definitionOrifice wear, erosion, deposits or mechanical damageCompare actual flow and spray pattern with a new nozzle of the same reference
Measured flow significantly above the reference value at the same pressureOrifice wear or erosion, or excessive actual pressureVerify pressure and replace the nozzle if wear is confirmed
Dripping after shutdownResidual pressure, valve or seal problem, or faulty / absent anti-drip systemInspect the shut-off and anti-drip components; do not assume the nozzle is clogged
Recurring blockageInadequate filtration, contamination, deposits or insufficient free passageReview filtration and fluid quality and consider a nozzle design with a larger free passage where appropriate

Clogged nozzle: 7 causes, cleaning and replacement guide →

Never insert metal wire, drill bits, needles or other hard objects into a precision nozzle orifice. Scratching or deforming the outlet can permanently alter flow rate, spray angle and liquid distribution.
For multi-nozzle spray bars: if one nozzle shows significant wear, measure several nozzles along the line under the same pressure. If wear is systematic and the nozzles have similar operating hours, replacing them as a matched set can help restore uniform flow distribution and coverage.

6Select and buy the replacement

Once you know the spray pattern, connection, flow rate at a known pressure, spray angle and material requirements, you have the main technical information needed to narrow down the replacement. At boquillasdeaspersion.es you can check references, technical data and prices and order directly online:

ConditionDetails
Minimum orderNone: order from 1 unit, useful for testing a reference before scaling up
Quantity discountsAutomatically applied in the cart: −3% (5–9), −5% (10–19), −7% (20–49), −10% (50–99), −12% (100+)
ShippingSpain and Portugal: fast 24 h shipping · Europe: 24–72 h · Rest of the world: 5–10 days
InvoiceOfficial invoice sent by email. EU businesses with a valid VAT number are not charged Spanish VAT in accordance with the conditions shown during purchase
PaymentCard, PayPal or bank transfer, with shipping, VAT and final order total visible before confirmation
View the online catalogue and compare spray nozzles → Technical data, product references, prices and stock information. Order from a single unit.

If you are still unsure which nozzle reference you need after following these steps, send us a clear photo of the nozzle together with the available working-pressure and flow-rate information via WhatsApp or through our contact page. Difusores de Agua, S.L. (BOCASPER) has manufactured and distributed industrial spray nozzles since 1987.

Frequently Asked Questions

How can I identify an installed spray nozzle if it has no marking?

Start by identifying the spray pattern, then measure the connection and actual flow rate at a known dynamic pressure. Also check the spray angle, material and mounting arrangement where possible. Comparing these parameters is much more reliable than selecting a replacement from appearance or thread size alone.

What does a number such as 6502 or 9515 engraved on a spray nozzle mean?

On many flat-fan nozzle ranges, the marking uses the first digits for nominal spray angle and the remaining digits for a flow-capacity code. Under a widely used convention, 9515 means a 95° flat fan with a nominal capacity of 1.5 US gpm at 40 psi, approximately 5.68 L/min at 2.76 bar. This coding system is not universal, so the manufacturer’s current technical data should always be checked.

Can I replace a spray nozzle from another manufacturer with an alternative model?

You can identify a potentially suitable alternative by comparing spray pattern, connection, spray angle, flow rate at the same pressure, material, dimensions and allowable operating conditions. Do not assume interchangeability from a trade name or nozzle family alone. Exact technical specifications should always be validated before replacement.

How do I measure a BSPT thread on a spray nozzle?

Use a caliper to measure the outside diameter of the male thread around the middle of the threaded section, not across the flats of the hexagonal body. A 1/4″ BSPT male thread has an outside diameter of approximately 13.2 mm and a 1/2″ BSPT male thread approximately 20.9 mm. The nominal inch designation is not the actual measured diameter.

If I double the pressure, does the nozzle flow rate double?

No. For the same fixed hydraulic nozzle and a liquid with hydraulic behaviour similar to water, flow varies approximately with the square root of the pressure ratio: Q₂ = Q₁ × √(P₂/P₁). Doubling the pressure therefore increases theoretical flow by approximately 1.41 times, not twice.

When should a spray nozzle be replaced instead of cleaned?

Replace the nozzle when the orifice is worn, eroded, corroded, scratched or permanently deformed, or when cleaning does not restore the specified flow rate and spray pattern. A particle or compatible removable deposit can normally be cleaned without replacing the nozzle, provided the orifice is not damaged.

Which material should I choose to replace a corroded nozzle?

The correct material depends on the fluid, concentration, temperature, pressure, abrasion, cleaning chemicals and operating environment. AISI 316 stainless steel may provide better chloride resistance than 304 in many applications, while PVDF is useful with many aggressive chemicals. However, compatibility must be checked for the exact process rather than selected from material name alone.

Is there a minimum order quantity for replacement spray nozzles?

No. At boquillasdeaspersion.es you can order from a single unit, which allows a nozzle reference to be tested before replacing or expanding a complete installation. Quantity discounts are applied automatically in the cart from 5 units, reaching 12% from 100 units.

Technical guide published by Difusores de Agua, S.L. (BOCASPER), manufacturers and distributors of industrial spray nozzles since 1987. Third-party trade names, markings and coding conventions are mentioned solely to assist with general product identification. Their inclusion does not imply affiliation, equivalence, compatibility or interchangeability between specific product references. Always verify the current technical specifications of the exact nozzle before installation.