Identify your nozzle without a technical data sheet: model, BSPT thread, marking 6502/9515, flow rate and material. Find the replacement part and buy it from as little as 1 unit.
To identify an installed spray nozzle, check the spray pattern, thread, flow rate at a known pressure, spray angle, material and mounting configuration. The pattern and thread identify the likely nozzle family; flow rate, angle and material then help determine the correct replacement.
If you have a worn, clogged or damaged spray nozzle and do not know which replacement to order, this guide takes you through the identification process step by step. You do not necessarily need the original manufacturer’s catalogue: you need to observe the spray pattern and check the main measurable specifications. At the end, you can match these characteristics to the appropriate BOCASPER nozzle family and buy online with no minimum order quantity.
- Identify the spray pattern while the nozzle is operating or, where possible, from the outlet geometry.
- Measure the thread with a caliper and compare it with the BSPT dimensions.
- Read the nozzle marking and check whether it encodes spray angle and nominal capacity.
- Identify the material using appearance, weight and documentation where available.
- Decide whether the nozzle should be cleaned, the system corrected or the nozzle replaced.
- Select the replacement by spray family, connection, flow rate, angle and material.
1Identify the spray pattern
The spray pattern is one of the most important selection criteria and cannot be determined from the thread alone. If the system can be operated safely, observe the spray against a suitable background or target. If it cannot, the outlet geometry and internal design may provide useful clues, although the actual spray pattern should ultimately be confirmed from technical data or an operating test.
| What you see | Typical outlet / design clue | Spray pattern | Typical application | BOCASPER family |
|---|---|---|---|---|
| Flat sheet with a linear impact pattern | Elongated or shaped outlet, or deflector design | Flat fan / water curtain | Linear washing, rinsing, spray bars and surface coverage | CA, CC, CW and CV Series |
| Filled circular spray pattern | Round outlet with an internal vane, insert or swirl geometry depending on the design | Full cone | Cooling, wetting, washing and general circular coverage | BA, BB, BC and BS Series |
| Ring-shaped spray with lower liquid density in the centre | Round outlet with an internal or tangential swirl arrangement | Hollow cone | Cooling towers, humidification, gas treatment and dust control | AA, AB and AC Series |
| Fine mist or small droplets | Small hydraulic passage, atomising geometry and sometimes an integrated filter | Fine spray / mist | Evaporative cooling, humidification and low-consumption spraying | DB, DC and other fine-spray Series |
| Straight, concentrated jet | Round outlet designed to minimise dispersion | Solid stream / straight jet | High-impact cleaning, localised cooling and long-reach applications | Solid-stream Series |
| Separate air and liquid connections | Body with two fluid connections or an air/liquid mixing arrangement | Twin-fluid / hydropneumatic atomisation | Fine mist, dry fog, humidification and controlled atomisation | G / GA Series |
If your original nozzle uses a trade name from another manufacturer —such as VeeJet, FullJet, WhirlJet, SpiralJet or similar names— use the spray-pattern and industrial-application guide to identify the general type of nozzle first. Trade names can help identify a product category, but they do not establish equivalence, compatibility or interchangeability between specific references.
2Measure the thread before ordering
One of the most common mistakes is ordering a nozzle as “half-inch” after measuring its outside diameter with a tape measure. BSPT pipe threads use nominal inch sizes, so the stated thread size does not correspond directly to the outside diameter measured in millimetres.
| Nominal BSPT thread | Approx. male outside diameter | Threads per inch | Typical nozzle applications |
|---|---|---|---|
| 1/8″ | 9.7 mm | 28 | Misting, anti-drip systems and low-flow applications |
| 1/4″ | 13.2 mm | 19 | Common size for flat-fan, full-cone and fine-spray nozzles |
| 3/8″ | 16.7 mm | 19 | Medium-flow industrial applications |
| 1/2″ | 20.9 mm | 14 | Higher-flow spraying, washing and industrial systems |
| 3/4″ | 26.4 mm | 14 | Spiral nozzles, larger flow rates and wide coverage |
| 1″ | 33.2 mm | 11 | Large-flow nozzles, tank systems and pipe-cleaning applications |
Measure the outside diameter of the male thread with a caliper, not the width across the flats of the hexagonal body. For a tapered thread, take the measurement around the middle of the threaded section. Also confirm whether the installation requires a male or female connection before ordering.
3Read the marking: it may reveal the spray angle and capacity
Many flat-fan spray-tip ranges use a four- or five-digit marking in which the first digits indicate the nominal spray angle and the remaining digits indicate a nominal flow-capacity code. A commonly used convention is illustrated below:
| Example marking | First digits | Capacity code | Typical interpretation in this coding convention |
|---|---|---|---|
| 6502 | 65° | 02 | 65° flat fan, nominal capacity 0.2 US gpm at 40 psi |
| 9515 | 95° | 15 | 95° flat fan, nominal capacity 1.5 US gpm at 40 psi |
| 11004 | 110° | 04 | 110° flat fan, nominal capacity 0.4 US gpm at 40 psi |
| 8003 | 80° | 03 | 80° flat fan, nominal capacity 0.3 US gpm at 40 psi |
For metric conversion, 1 US gpm ≈ 3.785 L/min and 40 psi ≈ 2.76 bar. Under the coding convention above, a 9515 therefore corresponds to approximately 5.68 L/min at 40 psi. If the BOCASPER reference is specified at 3 bar, correct the flow for pressure before comparing the two values.
If there is no readable marking: measure the actual flow rate
Operate the nozzle at a known dynamic pressure, collect its discharge for a measured period and calculate the volume per minute. For water and other liquids with similar hydraulic behaviour, the flow of the same fixed hydraulic nozzle can be estimated at another pressure using:
Q₂ = Q₁ × √(P₂ / P₁)
Use the same pressure units for P₁ and P₂. The relationship is an approximation for the same nozzle and comparable fluid properties within the nozzle’s normal operating range. It should not be applied blindly to twin-fluid air/water nozzles, adjustable nozzles, eductors, rotary equipment or other devices whose performance depends on additional variables.
Doubling pressure does not double the flow rate. For a conventional fixed hydraulic nozzle, it increases theoretical flow by approximately √2 = 1.41 times.
Flow rate, pressure and K-factor guide → Spray angle and coverage calculator →
4Identify the nozzle material
Material affects chemical compatibility, temperature capability, corrosion resistance, wear and service life. Appearance, weight and magnetic response can provide useful clues, but they are not sufficient to identify an exact alloy or polymer grade. For critical applications, confirm the material from the product marking, technical documentation or supplier.
| Typical clue | Possible material | Common strengths | Important limitation |
|---|---|---|---|
| Low-density engineering plastic; often natural, white, black or coloured | Polypropylene (PP) | Good resistance to many aqueous chemicals, low weight and economical cost | Temperature, pressure, UV exposure and chemical limits depend on the specific PP grade |
| Hard, smooth, rigid engineering plastic; usually denser than PP | Delrin / POM / acetal | Good dimensional stability, stiffness and wear characteristics | Chemical compatibility must be checked, particularly with strong acids and oxidising agents |
| Dense metal with yellow or gold appearance | Brass | Machinability, clean-water applications, compressed air and economical industrial use | Corrosion, dezincification and regulatory suitability depend on water chemistry and the exact alloy |
| Dense silver-grey metal; may be non-magnetic or weakly magnetic depending on grade and processing | Stainless steel, commonly AISI 303 / 304 / 316 | Mechanical strength, temperature capability and good corrosion resistance | Magnetism cannot reliably distinguish 303, 304 and 316; chloride resistance also varies by grade and conditions |
| White or cream engineering fluoropolymer, relatively dense for a plastic | PVDF | Excellent resistance to many aggressive chemicals and corrosive environments | Higher cost; pressure and temperature limits must be checked for the exact component |
Practical rule: if the nozzle being replaced has failed through corrosion, erosion or chemical attack, investigate the cause before installing the same material again. An eroded orifice may progressively increase flow and alter the spray distribution even when the nozzle still appears to operate.
Material selection and technical calculators →
5Clean, correct the system or replace the nozzle?
A poor spray pattern does not automatically mean that the nozzle is clogged, and a blockage does not automatically mean that the nozzle needs replacing. Diagnose the cause before changing components:
| Symptom | Possible cause | Recommended first action |
|---|---|---|
| Deflected, streaked or asymmetrical spray | Particle, deposit, damaged orifice or incorrect orientation | Inspect and clean using a compatible method; replace the nozzle if the orifice is damaged |
| Weak or incomplete spray pattern | Insufficient dynamic pressure, restricted filter, valve or supply problem | Measure pressure close to the nozzle and inspect the supply system before replacing it |
| Ragged edges or progressive loss of spray definition | Orifice wear, erosion, deposits or mechanical damage | Compare actual flow and spray pattern with a new nozzle of the same reference |
| Measured flow significantly above the reference value at the same pressure | Orifice wear or erosion, or excessive actual pressure | Verify pressure and replace the nozzle if wear is confirmed |
| Dripping after shutdown | Residual pressure, valve or seal problem, or faulty / absent anti-drip system | Inspect the shut-off and anti-drip components; do not assume the nozzle is clogged |
| Recurring blockage | Inadequate filtration, contamination, deposits or insufficient free passage | Review filtration and fluid quality and consider a nozzle design with a larger free passage where appropriate |
Clogged nozzle: 7 causes, cleaning and replacement guide →
6Select and buy the replacement
Once you know the spray pattern, connection, flow rate at a known pressure, spray angle and material requirements, you have the main technical information needed to narrow down the replacement. At boquillasdeaspersion.es you can check references, technical data and prices and order directly online:
| Condition | Details |
|---|---|
| Minimum order | None: order from 1 unit, useful for testing a reference before scaling up |
| Quantity discounts | Automatically applied in the cart: −3% (5–9), −5% (10–19), −7% (20–49), −10% (50–99), −12% (100+) |
| Shipping | Spain and Portugal: fast 24 h shipping · Europe: 24–72 h · Rest of the world: 5–10 days |
| Invoice | Official invoice sent by email. EU businesses with a valid VAT number are not charged Spanish VAT in accordance with the conditions shown during purchase |
| Payment | Card, PayPal or bank transfer, with shipping, VAT and final order total visible before confirmation |
If you are still unsure which nozzle reference you need after following these steps, send us a clear photo of the nozzle together with the available working-pressure and flow-rate information via WhatsApp or through our contact page. Difusores de Agua, S.L. (BOCASPER) has manufactured and distributed industrial spray nozzles since 1987.
Frequently Asked Questions
How can I identify an installed spray nozzle if it has no marking?
Start by identifying the spray pattern, then measure the connection and actual flow rate at a known dynamic pressure. Also check the spray angle, material and mounting arrangement where possible. Comparing these parameters is much more reliable than selecting a replacement from appearance or thread size alone.
What does a number such as 6502 or 9515 engraved on a spray nozzle mean?
On many flat-fan nozzle ranges, the marking uses the first digits for nominal spray angle and the remaining digits for a flow-capacity code. Under a widely used convention, 9515 means a 95° flat fan with a nominal capacity of 1.5 US gpm at 40 psi, approximately 5.68 L/min at 2.76 bar. This coding system is not universal, so the manufacturer’s current technical data should always be checked.
Can I replace a spray nozzle from another manufacturer with an alternative model?
You can identify a potentially suitable alternative by comparing spray pattern, connection, spray angle, flow rate at the same pressure, material, dimensions and allowable operating conditions. Do not assume interchangeability from a trade name or nozzle family alone. Exact technical specifications should always be validated before replacement.
How do I measure a BSPT thread on a spray nozzle?
Use a caliper to measure the outside diameter of the male thread around the middle of the threaded section, not across the flats of the hexagonal body. A 1/4″ BSPT male thread has an outside diameter of approximately 13.2 mm and a 1/2″ BSPT male thread approximately 20.9 mm. The nominal inch designation is not the actual measured diameter.
If I double the pressure, does the nozzle flow rate double?
No. For the same fixed hydraulic nozzle and a liquid with hydraulic behaviour similar to water, flow varies approximately with the square root of the pressure ratio: Q₂ = Q₁ × √(P₂/P₁). Doubling the pressure therefore increases theoretical flow by approximately 1.41 times, not twice.
When should a spray nozzle be replaced instead of cleaned?
Replace the nozzle when the orifice is worn, eroded, corroded, scratched or permanently deformed, or when cleaning does not restore the specified flow rate and spray pattern. A particle or compatible removable deposit can normally be cleaned without replacing the nozzle, provided the orifice is not damaged.
Which material should I choose to replace a corroded nozzle?
The correct material depends on the fluid, concentration, temperature, pressure, abrasion, cleaning chemicals and operating environment. AISI 316 stainless steel may provide better chloride resistance than 304 in many applications, while PVDF is useful with many aggressive chemicals. However, compatibility must be checked for the exact process rather than selected from material name alone.
Is there a minimum order quantity for replacement spray nozzles?
No. At boquillasdeaspersion.es you can order from a single unit, which allows a nozzle reference to be tested before replacing or expanding a complete installation. Quantity discounts are applied automatically in the cart from 5 units, reaching 12% from 100 units.
Technical guide published by Difusores de Agua, S.L. (BOCASPER), manufacturers and distributors of industrial spray nozzles since 1987. Third-party trade names, markings and coding conventions are mentioned solely to assist with general product identification. Their inclusion does not imply affiliation, equivalence, compatibility or interchangeability between specific product references. Always verify the current technical specifications of the exact nozzle before installation.
Applying products to crops? See also our guide to spray nozzles for agricultural applications.