Fast shipping
Products available from stock
Automatic quantity discounts
No minimum order
UK: Free DAP Shipping over €400

Industrial Spray Systems: Applications, Design and Nozzle Selection

Design industrial spray systems for washing, cleaning, cooling, humidification, coating and dust control by correctly selecting nozzles, flow rate, pressure, coverage and materials.

Technical guide and component selection

Industrial spray systems

Design washing, cleaning, cooling, coating, humidification and dust control installations with the right spray pattern, flow rate, pressure and material.

  • Selection by application
  • Flow rate and coverage calculation
  • Buy from one unit
Applications of industrial spray systems for washing, cooling, humidification, coating and dust control
Nozzles, piping, filtration, pump, regulation and control form a single system.

Concept and components

What is an industrial spray system?

It is an assembly designed to transport, regulate and atomise a liquid onto a surface, a product, a gas stream or an environment. The nozzle defines the final pattern, but its performance depends on the whole installation.

1Tank or supply
2Filtration
3Pump and pressure
4Manifold and control
5Nozzle and pattern

An error in filtration, pipe diameter, available pressure or overlap can prevent a suitable nozzle from producing the expected result.

?

Review the terminology before choosing a type

Nozzle, diffuser, atomiser, sprayer… are different names for the same component. See the full glossary with the 5 spray patterns and the key technical parameters.

See terminology glossary →

Visual selection

Choose the spray pattern

Each card uses the official main image of its product category. If the image is not available, the technical diagram is kept to avoid gaps.

Flat fan nozzle and water curtain category
Category main image

Flat fan or flat jet

Linear distribution with defined edges. Suitable for surface washing, tunnels, spray bars and uniform application.

  • Washing
  • Rinsing
  • Coating
See water curtains →
Full cone nozzle category
Category main image

Full cone

Complete circular coverage, with liquid also distributed in the centre. Useful for washing, cooling and wetting.

  • Full coverage
  • Cooling
  • Washing
See full cone nozzles →
Hollow cone nozzle category
Category main image

Hollow cone

Forms a circular ring with less liquid in the centre. Suitable for cooling, gases and dust control.

  • Circular ring
  • Gases
  • Dust
See hollow cone nozzles →
Fine spray nozzle and atomiser category
Category main image

Fine spray

Fine droplets with low liquid consumption. For humidification, evaporative cooling, odour control and light applications.

  • Low consumption
  • Micro-droplet
  • Ambient
See fine spray →
Solid stream or straight jet nozzle category
Category main image

Solid stream

Maximum impact concentrated on one point. Suitable for cutting, dislodging, spot cleaning and long-distance reach.

  • High impact
  • Reach
  • Spot cleaning
See solid stream nozzles →
Air atomising air and water nozzle category
Category main image

Air and water atomising

Compressed air helps produce very small, controllable droplets. For fine mist, dust and demanding coatings.

  • Fine mist
  • Precise control
  • Two fluids
See air atomising nozzles →
→

Nozzle catalogue by spray pattern

See the full spray nozzle catalogue by pattern before choosing a reference.

See spray nozzle catalogue →

Industrial applications

Configure the system to suit the process

Open each application to see the usual pattern, the parameters to check and the mistakes to avoid.

Recommended category for industrial washing and cleaning systems
Category: flat fan
Industrial washing and cleaning

Usual patterns: flat fan for linear cleaning; full cone for circular coverage; solid stream for localised dirt; 360° heads for tanks.

  • Define impact level and distance.
  • Calculate the overlap between nozzles.
  • Check total flow rate and pump capacity.
  • Fit filtration matched to the smallest orifice.
How to reduce water consumption →
Recommended category for industrial cooling systems
Category: hollow cone
Cooling and thermal control

Usual patterns: full cone for uniform cooling; hollow cone for liquid-gas exchange; fine spray when rapid evaporation is required.

  • Determine whether you need wetting or evaporation.
  • Check temperature, humidity and ventilation.
  • Avoid excessively fine droplets where drift is possible.
  • Select a material compatible with the temperature and the fluid.
See hollow cone solutions →
Recommended category for industrial coating and dosing
Category: air and water
Coating, painting and dosing

Usual patterns: flat fan for uniform bands and air atomising when droplet size and finish must be controlled.

  • Validate viscosity and surface tension.
  • Control the flow per nozzle, line speed and overlap.
  • Avoid pump pulsation.
  • Check the chemical compatibility of seals and materials.
See air and water atomising →
Recommended category for dust and emission control
Category: fine spray
Dust and emission suppression

Usual patterns: fine mist or air and water atomising for small particles; full or hollow cone for wetting, capture and gas scrubbing.

  • Match the droplet to the size and behaviour of the particle.
  • Consider wind, temperature and humidity.
  • Avoid over-wetting the product.
  • Protect small orifices with filtration.
See fine spray nozzles →
Nozzle category for cleaning tanks, vessels and containers
Category: tank cleaning
Cleaning tanks, vessels and pipes

Usual solutions: static or rotating heads for interior surfaces and nozzles with forward or rear jets for ducts.

  • Define diameter, geometry and access points.
  • Check the pressure and flow actually available at the point of use.
  • Consider the drainage of liquid and residues.
  • Validate material, temperature and cleaning product.
See tank and vessel cleaning →
Recommended category for humidification and general industrial processes
Category: full cone
Humidification and general processes

Usual patterns: fine spray for ambient conditions; full cone for wetting and coverage; hollow cone for liquid-gas contact.

  • Define target humidity and contact time.
  • Avoid unwanted condensation.
  • Check water quality and the risk of scaling.
  • Plan maintenance and access to the nozzles.
Guide to choosing a nozzle →

Process decision

Spray washing or immersion washing

Both methods can complement each other. The choice depends on part geometry, the type of soiling, cycle time, consumption and the degree of automation.

CriterionSpray washingImmersion washing
Main actionImpact, dislodging and coverage by means of jets.Prolonged contact between the liquid and the part.
GeometriesVery effective on accessible surfaces and continuous lines.Useful in cavities and complex submersible geometries.
Process controlAllows pressure, flow rate, temperature and time to be zoned.Depends on agitation, temperature, chemistry and bath renewal.
ConsumptionCan be optimised through recirculation, filtration and suitable nozzles.Requires maintaining and treating a bath volume.
AutomationEasy to integrate into tunnels, conveyors and cabinets.May require lifting, baskets or part handling.
Best choiceWhen directed impact, short cycles and zone control matter.When complete, prolonged contact is needed in hard-to-reach areas.

Technical design

How to size a spray system

The nozzle reference should be chosen after defining the result, not before. These five steps reduce errors in flow rate, coverage and pressure.

Define the result

Impact, coverage, droplet, reach, wetting or evaporation.

Select the pattern

Flat, full cone, hollow cone, fine, solid or air and water.

Calculate nozzles

Angle, height, effective width, spacing and overlap.

Add up the flow rate

Flow per nozzle × number of nozzles, with a reasonable technical margin.

Check the network

Pump, pressure losses, piping, filters, valves and control.

The catalogue pressure is not necessarily the pressure available at each nozzle. Calculate the pressure losses and check the pressure at the manifold during operation.

Frequently asked questions

Questions about spray systems

What components does an industrial spray system need?
It normally includes a supply or tank, filtration, a pump or available pressure, piping, valves, regulation, manifolds, nozzle holders and nozzles. Depending on the process it may also include sensors, solenoid valves, automatic control or recirculation.
How do you choose the right nozzle?
First the application and the required effect are defined. Then pattern, flow rate, pressure, angle, coverage, droplet size, impact, connection, material, temperature and liquid quality are compared.
Which pattern is best for industrial washing?
Flat fan is usually suitable for surfaces and spray bars; full cone for circular coverage; solid stream for localised impact; and 360° cleaning nozzles for tank interiors. The best option depends on the soiling, distance and geometry.
Does increasing the pressure always improve cleaning?
No. Increasing the pressure changes flow rate, impact, droplet size and consumption, but it can also produce mist, drift, wear or pump overload. The working range of the nozzle and of the complete system must be checked.
How do you prevent nozzles from clogging?
Through filtration matched to the nozzle free passage, periodic cleaning, controlled water quality and compatible materials. Where particles are present, non-clogging designs and larger orifices may be preferable.
Is spray washing or immersion washing better?
Spraying offers directed impact, fast cycles and zone control. Immersion makes contact with complex geometries easier. Many lines combine pre-washing, immersion, spraying and rinsing.

Do you need to select or size your system?

Tell us the application, liquid, available pressure, flow rate, temperature, material, connection and the area to be covered. With that information we can guide your selection more accurately.

See also our complete industrial nozzle catalogue to compare types and applications.

Item added to cart.