Design industrial spray systems for washing, cleaning, cooling, humidification, coating and dust control by correctly selecting nozzles, flow rate, pressure, coverage and materials.
Technical guide and component selection
Industrial spray systems
Design washing, cleaning, cooling, coating, humidification and dust control installations with the right spray pattern, flow rate, pressure and material.
- Selection by application
- Flow rate and coverage calculation
- Buy from one unit

Quick access
What does the system need to do?
Start with the result you want to achieve. Then adjust pattern, impact, droplet size, flow rate, pressure, coverage and material.
Concept and components
What is an industrial spray system?
It is an assembly designed to transport, regulate and atomise a liquid onto a surface, a product, a gas stream or an environment. The nozzle defines the final pattern, but its performance depends on the whole installation.
An error in filtration, pipe diameter, available pressure or overlap can prevent a suitable nozzle from producing the expected result.
Review the terminology before choosing a type
Nozzle, diffuser, atomiser, sprayer… are different names for the same component. See the full glossary with the 5 spray patterns and the key technical parameters.
See terminology glossary →Visual selection
Choose the spray pattern
Each card uses the official main image of its product category. If the image is not available, the technical diagram is kept to avoid gaps.
Flat fan or flat jet
Linear distribution with defined edges. Suitable for surface washing, tunnels, spray bars and uniform application.
See water curtains →Full cone
Complete circular coverage, with liquid also distributed in the centre. Useful for washing, cooling and wetting.
See full cone nozzles →Hollow cone
Forms a circular ring with less liquid in the centre. Suitable for cooling, gases and dust control.
See hollow cone nozzles →Fine spray
Fine droplets with low liquid consumption. For humidification, evaporative cooling, odour control and light applications.
See fine spray →Solid stream
Maximum impact concentrated on one point. Suitable for cutting, dislodging, spot cleaning and long-distance reach.
See solid stream nozzles →Air and water atomising
Compressed air helps produce very small, controllable droplets. For fine mist, dust and demanding coatings.
See air atomising nozzles →Nozzle catalogue by spray pattern
See the full spray nozzle catalogue by pattern before choosing a reference.
See spray nozzle catalogue →Industrial applications
Configure the system to suit the process
Open each application to see the usual pattern, the parameters to check and the mistakes to avoid.
Industrial washing and cleaning
Usual patterns: flat fan for linear cleaning; full cone for circular coverage; solid stream for localised dirt; 360° heads for tanks.
- Define impact level and distance.
- Calculate the overlap between nozzles.
- Check total flow rate and pump capacity.
- Fit filtration matched to the smallest orifice.
Cooling and thermal control
Usual patterns: full cone for uniform cooling; hollow cone for liquid-gas exchange; fine spray when rapid evaporation is required.
- Determine whether you need wetting or evaporation.
- Check temperature, humidity and ventilation.
- Avoid excessively fine droplets where drift is possible.
- Select a material compatible with the temperature and the fluid.
Coating, painting and dosing
Usual patterns: flat fan for uniform bands and air atomising when droplet size and finish must be controlled.
- Validate viscosity and surface tension.
- Control the flow per nozzle, line speed and overlap.
- Avoid pump pulsation.
- Check the chemical compatibility of seals and materials.
Dust and emission suppression
Usual patterns: fine mist or air and water atomising for small particles; full or hollow cone for wetting, capture and gas scrubbing.
- Match the droplet to the size and behaviour of the particle.
- Consider wind, temperature and humidity.
- Avoid over-wetting the product.
- Protect small orifices with filtration.
Cleaning tanks, vessels and pipes
Usual solutions: static or rotating heads for interior surfaces and nozzles with forward or rear jets for ducts.
- Define diameter, geometry and access points.
- Check the pressure and flow actually available at the point of use.
- Consider the drainage of liquid and residues.
- Validate material, temperature and cleaning product.
Humidification and general processes
Usual patterns: fine spray for ambient conditions; full cone for wetting and coverage; hollow cone for liquid-gas contact.
- Define target humidity and contact time.
- Avoid unwanted condensation.
- Check water quality and the risk of scaling.
- Plan maintenance and access to the nozzles.
Process decision
Spray washing or immersion washing
Both methods can complement each other. The choice depends on part geometry, the type of soiling, cycle time, consumption and the degree of automation.
| Criterion | Spray washing | Immersion washing |
|---|---|---|
| Main action | Impact, dislodging and coverage by means of jets. | Prolonged contact between the liquid and the part. |
| Geometries | Very effective on accessible surfaces and continuous lines. | Useful in cavities and complex submersible geometries. |
| Process control | Allows pressure, flow rate, temperature and time to be zoned. | Depends on agitation, temperature, chemistry and bath renewal. |
| Consumption | Can be optimised through recirculation, filtration and suitable nozzles. | Requires maintaining and treating a bath volume. |
| Automation | Easy to integrate into tunnels, conveyors and cabinets. | May require lifting, baskets or part handling. |
| Best choice | When directed impact, short cycles and zone control matter. | When complete, prolonged contact is needed in hard-to-reach areas. |
Technical design
How to size a spray system
The nozzle reference should be chosen after defining the result, not before. These five steps reduce errors in flow rate, coverage and pressure.
Define the result
Impact, coverage, droplet, reach, wetting or evaporation.
Select the pattern
Flat, full cone, hollow cone, fine, solid or air and water.
Calculate nozzles
Angle, height, effective width, spacing and overlap.
Add up the flow rate
Flow per nozzle × number of nozzles, with a reasonable technical margin.
Check the network
Pump, pressure losses, piping, filters, valves and control.
Calculation and checking
Tools to design the installation
Check flow rate, coverage, number of nozzles and the relationship between pressure and consumption before finalising your selection.
Flow rate by pressure
Estimate the new flow rate when the working pressure changes.
Open calculator → ∠Angle and coverage
Calculate the theoretical spray width from angle and distance.
Calculate coverage → NNozzles on a spray bar
Determine number, spacing and overlap for flat fan nozzles.
See method → KPressure, flow rate and K factor
Understand the mathematical relationship used to compare nozzles.
See formula → +All calculators
Access the full set of simulators and technical tools.
See tools → ?Technical enquiry
Send us the application, fluid, flow rate, pressure, temperature and connection.
Contact us →Frequently asked questions
Questions about spray systems
What components does an industrial spray system need?
How do you choose the right nozzle?
Which pattern is best for industrial washing?
Does increasing the pressure always improve cleaning?
How do you prevent nozzles from clogging?
Is spray washing or immersion washing better?
Do you need to select or size your system?
Tell us the application, liquid, available pressure, flow rate, temperature, material, connection and the area to be covered. With that information we can guide your selection more accurately.
See also our complete industrial nozzle catalogue to compare types and applications.