Technical guide to choosing, calculating and installing nozzles for disinfection arches for vehicles, machinery, equipment and industrial surfaces.
Nozzles for disinfection arches for vehicles and industrial equipment
How to choose the spray pattern, calculate coverage and flow, check materials and avoid the mistakes that make a gantry wet a lot but disinfect badly.
To cover a defined strip of a vehicle or piece of equipment, the usual choice is a flat-jet or water-curtain nozzle. For irregular surfaces a full cone may suit better; when very low consumption is needed, a fine spray compatible with the product. The final choice depends on the authorised dose, angle, distance, flow, real pressure, material and contact time.
A disinfection arch, also called a gantry, spray tunnel or sanitising arch, is a structure with several industrial nozzles aimed at whatever passes through. These outlets may also be described as jets, sprinklers or sprayers. Their job is not simply to “make mist”: they must deposit on the surfaces an amount of product consistent with the defined procedure, without leaving dry strips and without using more liquid than necessary.
That is why the gantry is only the support. The real result is determined by the product used, prior cleaning where applicable, the dose applied per surface, coverage, contact time and the hydraulic conditions reaching each nozzle. An installation can look uniform and still meet none of those requirements.
First, an essential distinction: surfaces yes; people no
Biocides must not be sprayed on people
This guide refers exclusively to vehicles, wheels, undersides, machinery, tools, trolleys, packaging, equipment and compatible surfaces. The World Health Organization advises against spraying disinfectants on people through tunnels, cabins or chambers because they are ineffective and may harm eyes, skin and airways. See the official WHO information on cleaning and disinfecting.
For surfaces, use only a product authorised for the specific use and follow its label and technical data sheet. Concentration, dose, application method, contact time, any rinsing, protective equipment and access restrictions are set by the authorised product; they are not determined by the nozzle. In Spain you can check products and authorisations in the biocides register of the Ministry of Health.
Key idea: the nozzle distributes the liquid, but on its own it does not turn spraying into a validated disinfection process. When the application is critical, the biosafety officer or a qualified professional must validate the whole procedure.
Where an industrial spray arch makes sense
Industrial vehicles
Application on the sides, front, top or compatible exterior surfaces of lorries, trailers and mobile machinery.
Wheels and undersides
Spraying directed at tyres, wheel arches and lower areas, where orientation and impact are especially important.
Trolleys and pallet trucks
Treatment of items that move between production areas, provided the material and the product are compatible.
Machinery and tools
Controlled coverage of equipment, tools or parts before entering an area with specific hygiene requirements.
Packaging and containers
Automated application on items in transit, with special attention to surface dose and the required contact time.
Livestock biosecurity
Access control for vehicles and equipment at farms, logistics centres and other facilities with a veterinary protocol.
Not all these applications need the same spray. A wide curtain may work well on a side, while a complex underside may need several aimed jets. The geometry of the object matters more than the shape of the arch.
How to choose the nozzle: a practical route in six steps
Define which surface must receive product
Separate sides, top, wheels, undersides and hidden areas. “Covering a vehicle” is not enough technical data: each zone has different distances and angles of incidence.
Start from the product label
Check authorised use, dilution, dose, application method, contact time, rinsing and safety. These data set the target; the nozzles are sized afterwards.
Choose the spray pattern
Use flat jet to create strips and overlaps; full cone to deliver liquid over a circular area; hollow cone or fine spray when lower flow is needed and the procedure allows small droplets.
Calculate coverage, number of nozzles and total flow
Distance and angle define the theoretical width. Total consumption is the sum of all the nozzles running at the same time, not the flow of a single one.
Check pressure, piping, filtration and material
The pump must sustain the total flow at the required pressure after losses. The material must be compatible with the fluid, and the filter must protect the smallest orifice in the system.
Test before replicating the assembly
Validate the real footprint, overlap, consumption and orientation with a few units. Then you can repeat the module and benefit from automatic quantity discounts.
Comparison of spray patterns
| Pattern | When it usually fits | Main advantage | What to watch |
|---|---|---|---|
| Flat jet / curtain | Sides, roof, wheels, bars and linear passages. | Forms a defined strip and allows overlaps to be organised. | Fan orientation, distance, edges and uniformity between nozzles. |
| Full cone | Irregular surfaces or areas where more liquid volume is wanted. | Distributes liquid within a complete circular footprint. | Higher potential consumption and risk of applying more liquid than necessary. |
| Hollow cone | Peripheral coverage, low consumption or spraying around an area. | Good atomisation with a ring-shaped distribution. | The centre receives less liquid; it must not be confused with a full cone. |
| Fine spray | Low-consumption applications on compatible equipment or surfaces. | Small droplets and good dispersion with little flow. | Drift, evaporation and inhalation; only if the product and the environment allow this method. |
The finest droplet does not always disinfect better. It can stay suspended, drift with the air or evaporate before delivering the required dose. For surfaces, the aim is sufficient, uniform deposition for the stated time, not to create a visually striking cloud.
See the real pattern before choosing the nozzle
Formulas allow pre-sizing, but a video of the nozzle running helps distinguish a flat curtain, a fine spray and an adjustable assembly. Use these visual tests to decide which family to compare; then confirm the data in the technical data sheet and the calculators.
Reading the video correctly: appearance alone does not prove the flow, the dose deposited or the effectiveness of the process. It serves to identify the pattern; the final selection must rely on measured data.
BOCASPER families worth comparing
Instead of choosing a reference by its name or thread, start with the family that produces the pattern you need. Within each category you can compare the flow, angle, material, pressure and connection of each model.
Water curtains
Flat fan to create lateral, overhead or frontal spray strips.
Compare the CC series →Wide opening
Wide pattern when you need to cover more width from a side or aimed position.
Compare the CW series →Anti-drip fine spray
Low consumption and anti-drip shut-off for controlled applications on equipment and surfaces.
Compare the DC series →Low-consumption atomisation
Hollow cone and fine droplets for installations where flow must be especially controlled.
Compare the DF series →Pipe clamps
Quick mounting of nozzles on pipework without machining a threaded connection at every point.
See the QC clamps →Aimers and ball joints
They let you correct the jet direction and aim at wheels, undersides or specific areas.
See the aimers →Compare first; buy later
You can buy single units to validate pattern, pressure and coverage before completing the whole arch.
How to pre-size the arch before buying
For a first calculation you need, at minimum, the width and height of the area to cover, the distance between nozzle and surface, the nominal angle, the flow of each nozzle at a known pressure, the expected working pressure and the number of outlets that will run simultaneously.
1. Theoretical coverage
W = 2 × H × tan(θ ÷ 2)W is the width covered, H the perpendicular distance and θ the nominal spray angle.
2. Flow at another pressure
Q₂ = Q₁ × √(P₂ ÷ P₁)Approximation for a fixed-orifice hydraulic nozzle and a liquid that behaves like water.
3. Simultaneous flow
Q total = N × Q boquillaN is the number of nozzles open at the same time. Then add the needs of other branches of the system.
Indicative example: a 3-metre overhead bar
Assume an 80° nozzle placed 0.40 m from the surface with a flow of 1.2 L/min at the working point:
The example is for understanding the method, not for copying a universal spacing. The real angle can narrow or distort because of insufficient pressure, viscosity, wind, wear or a different working distance. In addition, a pump’s nominal flow does not guarantee it can deliver that flow at the required pressure.
Recommended calculator route
Pressure, pump and piping: the mistake that appears when all the nozzles open
A test with a single nozzle can work perfectly and fail when the full arch is opened. As outlets multiply, total flow rises, losses appear in pipes, filters, elbows, valves and height differences, and the pressure available at the farthest points can drop.
- Check the pump curve: it must deliver the simultaneous flow at the required pressure, not merely state a maximum pressure or a maximum flow separately.
- Measure at the worst point: a reading next to the pump does not show what pressure the last nozzle receives.
- Avoid undersized piping: high velocity increases losses and can unbalance the pattern between the start and end of the arch.
- Split the system if appropriate: on large gantries it can help to feed from the centre, from both ends or to create independent branches.
- Regulate and monitor: a pressure gauge, regulator, solenoid valve and isolation valves help repeat the same cycle.
To review these variables step by step, use the guide to sizing installations with several nozzles.
Materials, filtration and chemical compatibility
Stainless steel is not automatically compatible with every disinfectant, and a plastic is not automatically a poor-quality option. Concentration, pH, oxidants, chlorides, temperature and exposure time can completely change the selection.
| Variable | Why it matters | What to check |
|---|---|---|
| Nozzle material | It can corrode, swell, crack or contaminate the process. | The manufacturer’s chemical table with the real concentration and temperature. |
| Seals and valves | The nozzle’s compatibility does not guarantee that of the rest of the circuit. | Elastomers, pump, piping, adhesives, tanks and seals. |
| Orifice size | Small passages clog sooner and alter the flow more. | Liquid quality, particles, precipitates and correct dilution. |
| Filtration | It protects the pattern and reduces downtime, but a restrictive filter causes pressure drop. | Recommended mesh for the reference and sufficient flow with the filter loaded. |
| Temperature | It changes viscosity, material resistance and seal behaviour. | Limits of all components, not just the nozzle. |
Use the materials selector and guide for nozzles as a first screening, then confirm compatibility with the documentation of the chemical product and of each component.
An assembly that makes adjustment and maintenance easy
A useful arch must be adjustable, cleanable and isolable without dismantling the whole structure. These elements often make more difference than adding nozzles without criteria:
- Accessible filter sized for the total flow.
- Pressure gauge close to the nozzles, not only at the pump.
- Pressure regulator to repeat working conditions.
- Solenoid valve positioned to reduce the volume that stays pressurised.
- Shut-off valves to isolate branches during maintenance.
- Pipe clamps or aimers that let you correct each jet.
- Drainage and rinsing procedure when the product data sheet requires it.
- Safe access to inspect and replace nozzles.
If you are going to install on a pipe, see the guide to mounting with pipe clamps and check outside diameter, thread, seal, orientation and permissible pressure before buying.
Common problems and what to check first
| Symptom | Probable cause | First check |
|---|---|---|
| Dry strips appear | Excessive spacing, little overlap, smaller real angle or poor orientation. | Measure the footprint on the real surface and recalculate height and spacing. |
| The last nozzles spray less | Head losses, small piping, restrictive filter or insufficient pump. | Measure pressure with all nozzles open at the start and at the end. |
| The arch drips when it stops | Residual pressurised volume, distant valve or lack of an anti-drip system. | Check the solenoid valve location, drainage and closing pressure. |
| Outlets clog | Inadequate filtration, precipitates, incorrect mixing or dirt in the line. | Inspect the filter, tank, dilution and the diameter of the smallest orifice. |
| Too much mist forms | Droplet too fine, excessive pressure, air current or unsuitable nozzle. | Review the method permitted by the product and prioritise deposition on the surface. |
| Consumption is higher than expected | Higher real pressure, more simultaneous nozzles, wear or too long a cycle. | Measure pressure and volume consumed over a complete cycle. |
Maintenance to preserve flow and pattern
Uniformity does not maintain itself. A partly clogged, eroded or differently angled nozzle can break the overlap of the entire bar. It is advisable to record the initial pattern and compare it at inspections.
- Flush the piping before fitting the nozzles and after any work on the circuit.
- Check and clean the filters at a frequency based on the system’s real dirtiness.
- Do not enlarge orifices with wires, drill bits or metal tools.
- Check leaks, seals, orientation and pressure with all outlets active.
- Periodically compare the measured flow with the initial value; wear usually increases consumption.
- Follow the draining, rinsing or storage procedure indicated for the product used.
Frequently asked questions about disinfection arches
What is the best nozzle for a vehicle disinfection arch?
There is no universal reference. Flat jet is usually a good starting point for sides and bars because it creates a strip that is easy to overlap. For irregular areas a full cone may fit; for low consumption, a fine spray compatible with the product. The decision must check flow, pressure, distance, dose, material and vehicle geometry.
How many nozzles does an arch need?
It depends on the width and height to cover, the distance to the surface, the real angle and the desired overlap. First calculate the coverage of one nozzle, set the spacing and then check the total flow. The spray bar calculator gives a first estimate.
What working pressure does it need?
The valid pressure is the one given for the chosen nozzle that produces its expected pattern and flow. It must be measured with all the nozzles running and after the losses in piping, filters, valves and height difference. A single pressure cannot be set for all arches.
Can disinfectant be sprayed on people?
We do not recommend spraying biocides on people. The WHO advises against tunnels, cabins or chambers that spray disinfectants on individuals because they are ineffective and may have harmful effects. This guide is limited to vehicles, equipment and compatible surfaces.
Which disinfectant product should be used?
It must be a product authorised for the surface, the sector and the intended application method. Follow the label and data sheet exactly for concentration, dose, contact time, rinsing, protection and access restrictions. The nozzle does not replace that authorisation.
Does a finer droplet improve disinfection?
Not necessarily. Fine droplets can improve dispersion, but they also increase drift, evaporation and the risk of inhalation. The right droplet is the one that deposits the required dose uniformly on the surface within the conditions allowed by the product.
How is total consumption calculated?
Multiply the flow of one nozzle at the real pressure by the number of nozzles open at the same time. If there are branches that work at different times, calculate each scenario. The pump must provide the flow of the most demanding scenario while maintaining the required pressure.
Which material suits chemical products?
It depends on the product, concentration, temperature and exposure time. Stainless steel, PVDF, PP and brass have different resistances. Also confirm the compatibility of seals, pump, piping, tank and valves, not just the nozzle’s.
Does BOCASPER design or install the complete arch?
BOCASPER supplies nozzles and accessories and provides data sheets, guides and calculators to help with selection and pre-sizing. It does not design or install the complete hydraulic network. Final validation is the responsibility of the installer, the process owner or a qualified professional.
Calculate first. Choose nozzles with data.
Compare pattern, flow, pressure, material, thread and assembly. Then test one unit before replicating the whole system.
Related guides to complete your selection
Technical scope: the linked formulas and calculators provide an indicative pre-sizing. Real behaviour may vary due to viscosity, density, temperature, wear, tolerances, wind, filtration, head losses and geometry. For regulated or critical processes, validate the system by testing and with the responsible professional.